Negative pressure unit for filtering asbestos contaminated room air via a 3-stage filter unit. Fan and filter separated, with 2 separate standard filter units FG 500.
air capacity with filter max.12000 m³/h
- Energy-efficient and performance-optimized fan with high capacity
- smooth and easy-to-decontaminate housing
- light and sturdy housing
- threefold sealed HEPA filter
- Easy, very low-emission filter change in 3 minutes
- Automatic soft start, even after power failure
- All operating control and functional elements are shock-protected
2 control options
Control SE
For power regulation, the NPU is supplied with manual stepless speed control.
A necessary filter change is indicated by a manometer.
Control SE+
The NPU is supplied with a manual / automated stepless control for power regulation.
A necessary filter change is indicated by a manometer.
Options
Technical data
All data on air performance and volume flows are taking into account a measuring tolerance of ± 15% based on the measuring range end value, determined in a multi-point measuring method with a calibrated vane anemometer.
- dimensions fan (LxWxH): 1180 x 785 x 955 mm
- dimensions FG 500 (LxWxH): 715 x 720 x 1150 mm
- weight fan: 110 kg
- weight FG 500 incl. filter: 63 kg
- air capacity without filter: max. 15000 m³/h
- + deconta H13 filter: max. 13000 m³/h
- + pre- and intermediate filter (EU3, EU4): max. 12000 m³/h
- power connection: 400 V
- power consumption: 9 A
- hose connection: Suction option, exhaust air ND 450
- filter system: 3-stage
- HEPA filter acc. to EN 1822 class H13 or H14
ATTENTION! Only original deconta HEPA filter ensure the machine safety!