Negative pressure unit for filtering asbestos contaminated room air via a 2-stage filter unit.
air capacity with filter max. 2300 m³/h
- energy-efficient and performance-optimized fan with high capacity
- smooth and easy-to-decontaminate housing
- light and sturdy housing
- threefold sealed HEPA filter
- easy, very low-emission filter change
- stainless and powder-coated housing
- automatic soft start, even after power failure
- automatic closing exhaust flap
2 control options
Control SE
For power regulation, the NPU is supplied with manual stepless speed control.
A necessary filter change is indicated by a manometer.
Control SE+
The NPU is supplied with a manual / automated stepless control for power regulation.
A necessary filter change is indicated by a manometer.
Technical data
All data on air performance and volume flows are taking into account a measuring tolerance of ± 15% based on the measuring range end value, determined in a multi-point measuring method with a calibrated vane anemometer.
- Dimensions in mm (LxWxH): 745 x 410 x 790
- Weight incl. filter: 45 kg
- Voltage: 110 V / 230 V
- Power consumption: 2,6 A (230 V) / 4,6 A (110 V)
- Motopower: 0,385 kW (230 V) / 0,375 kW (110 V)
- Volume flow without filter: 3000 m³/h (230 V) / 2700 m³/h (110 V)
- Volumen flow with filter: 2300 m³/h (230 V) / 2250 m³/h (110 V)
- Filter stages: 2
- HEPA filter dimensions in mm:305 x 610 x 292
- Hose connection suction: NW 300
- Hose connection exhaust: NW 300
- Chassis with wheels: integrated
ATTENTION! Only original deconta HEPA filters ensure machine safety!