Negative pressure unit for filtering asbestos contaminated room air via a 3-stage filter unit.
air capacity with filter max. 1650 m³/h
- energy-efficient and performance-optimized fan with high capacity
- smooth and easy-to-decontaminate housing
- light and sturdy housing
- threefold sealed HEPA filter
- easy, very low-emission filter change in 3 minutes
- automatic soft start, even after power failure
- all operating control and functional elements are shock-protected
- stackable housings, thus low space requirement
2 control options
Control SE
For power regulation, the NPU is supplied with manual stepless speed control.
A necessary filter change is indicated by a manometer.
Control SE+
The NPU is supplied with a manual / automated stepless control for power regulation.
A necessary filter change is indicated by a manometer.
Options
Technical data
All data on air performance and volume flows are taking into account a measuring tolerance of ± 15% based on the measuring range end value, determined in a multi-point measuring method with a calibrated vane anemometer.
- dimensions (LxBxH): 770 x 410 x 410 mm
- weight incl. filter: 27,5 kg
- air capacity without filter: max. 2300 m³/h (230V) max. 2000 m³/h (110V)
- + deconta H13 filter: max. 1800 m³/h (230V) max. 1500 m³/h (110V)
- + pre- and intermediate-filter: (EU3, EU4) max. 1650 m³/h (230V) max. 1350 m³/h (110V)
- power connection: 100-120V / 230 V
- power consumption: 2,5 A (230V) 4,0 A (110V)
- hose connection: Option
- filter system 3-stages
- HEPA filter acc. to EN 1822 class H13 or H14
ATTENTION! Only original deconta HEPA filter ensure the machine safety!