Deconta

smart dec S 300smart dec S 300smart dec S 300smart dec S 300smart dec S 300smart dec S 300

Negative Pressure Unit smart dec S 300

Negative pressure unit for filtering asbestos contaminated room air via a 2-stage filter unit.

  • Control

    Control

    2 control options

    Control SE
    For power regulation, the negative pressure unit is supplied with a manual stepless regulation.
    A necessary filter change is indicated by a manometer.

     

    Control SRE connect

    IoT (Internet of Things) => Devices with SRE connect control can be remotely controlled and monitored with any Internet-enabled PC, mobile phone or tablet.
    For power regulation, the NPU is supplied with a control via a touch display to measure and regulate the negative pressure and / or the flow rate.
    The negative pressure is measured between the work area and a reference point to be defined (adjacent rooms) and kept at the set point value by continuous speed control of the electric fan.
    The volume flow is measured in the device and kept at the set point value by continuous speed control of the electric fan.
    Likewise, a manual control is possible.
    A filter sensor (option with connect BASIC) monitors the particle concentration in the exhaust air and triggers an optical and acoustic alarm if a value of 100 particles per liter is permanently exceeded.

     

    2 connect packages

    All connect functions are free for 6 months, then for a fee.

    connect BASIC function:

    • Localisation
    • Documentation
    • Remote Monitoring

    connect PRO function:

    All connect BASIC functions, plus ...

    • Remote control
    • Remote maintenance
    • Predictive maintenance
    • Particle sensor for filter monitoring
  • Documents | Technical data

    Documents | Technical data


    download instructions manual as PDF file


    Technical data:

    All data on air performance and volume flows are taking into account a measuring tolerance of ± 15% based on the measuring range end value, determined in a multi-point measuring method with a calibrated vane anemometer.

    • Dimensions in mm (LxWxH): 845 x 718 x 790
    • Weight incl. filter: 66 kg
    • Voltage: 110 V / 230 V
    • Power consumption: 4,0 A (230 V) / 2x 4,6 A (110 V)
    • Motopower: 0,78 kW (230 V) / 2x 0,375 kW (110 V)
    • Volume flow without filter: 6000 m³/h (230 V) / 5000 m³/h (110 V)
    • Volumen flow with filter: 4200 m³/h (230 V) / 4000 m³/h (110 V)
    • Filter stages: 2
    • HEPA filter dimensions in mm: 610 x 610 x 292
    • Hose connection suction: NW 450
    • Hose connection exhaust: NW 450
    • Chassis with wheels: integrated


    ATTENTION! Only original deconta HEPA filters ensure machine safety!