Deconta

smart dec S 50smart dec S 50smart dec S 50smart dec S 50smart dec S 50smart dec S 50

Negative Pressure Units smart dec S 50

Negative pressure unit for filtering asbestos contaminated room air via a 2-stage filter unit.

  • energy-efficient and performance-optimized fan with high capacity
  • smooth and easy-to-decontaminate housing
  • light and sturdy housing
  • threefold sealed HEPA filter
  • easy, very low-emission filter change in 3 minutes
  • automatic soft start, even after power failure
  • all operating control and functional elements are shock-protected
  • stackable housings, thus low space requirement
  • automatic closing exhaust flap
  • Filter

    Filter

  • Control

    Control

    Control SE

    For power regulation, the NPU is supplied with manual stepless speed control.
    A necessary filter change is indicated by a manometer.

  • Documents | Technical data

    Documents | Technical data

     

    download intructions manual as PDF file

     

    Technical data:

    All data on air performance and volume flows are taking into account a measuring tolerance of ± 15% based on the measuring range end value, determined in a multi-point measuring method with a calibrated vane anemometer.

    • Dimensions (LxWxH): 530 x 386 x 397 mm
    • Weight incl. filter: 21,5 kg
    • Voltage: 110 V / 230 V
    • Power consumption: 2,4 A (110 V) / 1,2 A (230 V)
    • Motor power: 0,17 kW (110 V) / 0,21 kW (230 V)
    • Volume flow without filter:1500 m³/h (110 V) / 1700 m³/h (230 V)
    • Volume flow with filter: 700 m³/h (110 V) /   900 m³/h (230 V)
    • Filter stages: 2
    • Suction flange: ND 150
    • HEPA filter: acc. to EN 1822 class H13 or H14

    ATTENTION ! Only original deconta HEPA filters ensure machine safety!